| HSR-SLD152Z | HSR-SLD154Z | HSR-SLD2C152Z | HSR-SLD2C154Z |
| HSR-SLD152ZBI | HSR-SLD154ZBI | HSR-SLD2C152ZBI | HSR-SLD2C154ZBI |
| HSR-SLD152R | HSR-SLD154R | HSR-SLD2C152R | HSR-SLD2C154R |
| HSR-SLD152RBI | HSR-SLD154RBI | HSR-SLD2C152RBI | HSR-SLD2C154RBI |
| HSR-SLD252Z | HSR-SLD254Z | HSR-SLD2C252Z | HSR-SLD2C254Z |
| HSR-SLD252ZBI | HSR-SLD254ZBI | HSR-SLD2C252ZBI | HSR-SLD2C254ZBI |
| HSR-SLD252R | HSR-SLD254R | HSR-SLD2C252R | HSR-SLD2C254R |
| HSR-SLD252RBI | HSR-SLD254RBI | HSR-SLD2C252RBI | HSR-SLD2C254RBI |
| HSR-SLD402Z | HSR-SLD404Z | HSR-SLD2C402Z | HSR-SLD2C404Z |
| HSR-SLD402ZBI | HSR-SLD404ZBI | HSR-SLD2C402ZBI | HSR-SLD2C404ZBI |
| HSR-SLD402R | HSR-SLD404R | HSR-SLD2C402R | HSR-SLD2C404R |
| HSR-SLD402RBI | HSR-SLD404RBI | HSR-SLD2C402RBI | HSR-SLD2C404RBI |
– Slim type (22.4 ㎜)
– Wide range of rated load voltage 90 – 264 / 90 – 480 V a.c.
– High insulation between input and output
– Zero Cross / Random switching
– Optimal heat dissipation design, semi-permanent life
· Suffix code
■ CE certification type
| Model | Code | Information | ||||||
| HSR-SL | □ | □ | □ | □ | □ | □ |
|
|
| Input voltage | D |
|
||||||
| Contact | – |
|
||||||
| 2C |
|
|||||||
| Rated load current | 15 |
|
||||||
| 25 |
|
|||||||
| 40 |
|
|||||||
| Rated load voltage | 2 |
|
||||||
| 4 |
|
|||||||
| Operation method |
Z |
|
||||||
| R |
|
|||||||
| Option | – |
|
||||||
| BI |
|
|||||||
| ※ 2 contact : Only available for 15 A items (HSR-SLD2C152Z, HSR-SLD2C154Z) |
■ S mark type
| Model | Code | Information | ||||||
| HSR-SL | □ | □ | □ | □ | □ | -S |
|
|
| Input voltage | D |
|
||||||
| Contact | – |
|
||||||
| Rated load current | 15 |
|
||||||
| 25 |
|
|||||||
| 40 |
|
|||||||
| Rated load voltage | 2 |
|
||||||
| 4 |
|
|||||||
| Operation method |
Z |
|
||||||
· Specification
| Model | LOW | HSR-SLD152Z | HSR-SLD252Z | HSR-SLD402Z | |
| HIGH | HSR-SLD154Z | HSR-SLD254Z | HSR-SLD404Z | ||
| W×H×D (㎜) | 17.4×99×98.5 | 44.4×99×98.5 | |||
| Input | Rated Voltage | 5 – 24 V d.c. | |||
| Voltage use range | 4 – 32 V d.c. | ||||
| Impedance | Less than 4 kΩ | ||||
| Operation Voltage | More than 3 V d.c. | ||||
| Reset Voltage | Less than 1.5 V | ||||
| Load | Rated load voltage |
LOW | 90 – 264 V a.c. | ||
| HIGH | 90 – 480 V a.c. | ||||
| Peak voltage (No repetition) |
LOW | 600 V | |||
| HIGH | 800 V | 1200 V | |||
| Rated load current | 15 A | 25 A | 40 A | ||
| Frequency | 50/60 Hz (Dual usage) | ||||
| Input current 60㎐ (8.3 ms No repetition) |
LOW | 170 A | 260 A | 420 A | |
| HIGH | 170 A | 250 A | 370 A | ||
| Input current 50㎐ (10 ms No repetition) |
LOW | 160 A | 250 A | 400 A | |
| HIGH | 160 A | 230 A | 350 A | ||
| Leakage current | 20 ㎃ max. | ||||
| Output ON voltage dropping | 1.6 V (R.M.S) max. | ||||
| Zero cross Function | Available ( R type is not available) | ||||
| Response Time | 1/2 Cycle + 1 ms max. (R type below 1 ms) | ||||
| Insulating Resistance | 500 V d.c 100 ㏁(Between the input / output and case) | ||||
| Dielectric strength | 3,000 V a.c. (For 1 min at 60 Hz) | ||||
| Vibration resistance | 10 – 55 ㎐ Double amplitude : 1.5 ㎜ each X,Y and Z direction for 2 hours |
||||
| Shock resistance | 1,000 ㎨, X, Y, Z each axis 3 times | ||||
| Storage Temperature | -30 ℃ ~ 90 ℃ | ||||
| Ambient Temperature | 0 ℃ ~ 40 ℃ (Without condensation) | ||||
| Ambient Humidity | 45 ~ 85 %R.H. | ||||
| Weight | Approx 230 g | Approx 372 g | |||




Reviews